Firefighting Skid Unit Buying Guide
By Darley | Specifications reviewed November 3, 2026
What is a firefighting skid unit?
Darley Fast Attacks and KIMTEK Fire Skids are also referred to as slip-ons, slide-ins, and drop-in units. A firefighting skid unit combines a water tank, engine-driven pump, plumbing, and hose equipment on a platform designed to mount in a compatible pickup, UTV, or other vehicle. Options may include a reel, foam system, storage, or rescue area.
The tank carries the water, the pump supplies flow and pressure, and the hose delivers water to the nozzle. A skid unit gives a compatible pickup or UTV onboard water and pumping capability for firefighting in areas the vehicle can access.
Pickup configuration: Fast Attack 2 - Multipurpose Product photo; confirm the included equipment and options in your quote. View Fast Attack 2 Multipurpose | UTV configuration: FIRELITE Transport Deluxe Product photo; confirm the included equipment and options in your quote. View FIRELITE Deluxe |
Choose around three requirements: what your vehicle can carry, what flow and pressure your hose lay needs, and how much water you need between refills. Then compare hose deployment, foam options, storage, and cold-weather readiness.
Start with loaded weight
A unit that fits in the bed can still exceed the vehicle’s carrying capacity.
Read GPM and PSI together
Use the pressure available at your required flow, then account for the complete hose lay.
Plan the next refill
Tank capacity affects operating time and vehicle load. Compare both before ordering.
Compare skid unit flow, pressure, and tank capacity
Darley’s selection includes 200-gallon Fast Attack pickup units and KIMTEK FIRELITE UTV units with 55-, 70-, or 85-gallon tanks. The selection guidance below is a starting point for evaluating the exact configuration.
Read each GPM and PSI pair together. Published pump points do not establish the flow and pressure delivered at your nozzle through a particular installation.
On small screens, swipe the table sideways to see every column.
| Model | Pump performance | Water tank | When to compare |
|---|---|---|---|
| Fast Attack 1 - Economy FASU-1E | 13 HP Honda / Davey twin-impeller: 120 GPM at 40 PSI; 95 at 108; 60 at 133; 20 at 146. | 200 gal. | Compare for pickup brush-fire duties when its flow and pressure meet your hose requirements. |
| Fast Attack 2 - High Pressure FASU-2HP | 21 HP Honda: 120 GPM at 155 PSI; 75 at 230; 35 at 300. 18 HP Vanguard: 120 at 130; 75 at 210; 35 at 265. | 200 gal. | Compare for hose lays requiring greater pressure at the specified flow. |
| Fast Attack 2 - Multipurpose FASU-2MP | 2BE, listed Honda and Vanguard configurations: 375 GPM at 25 PSI; 300 at 45; 100 at 140. | 200 gal. | Compare for higher-volume duties with an adequate water supply and suitable plumbing. |
| FIRELITE Transport Darley FD-202 | 6.5 HP Darley-Davey: 65 GPM at 48 PSI; 50 at 81; 20 at 120. | 55 or 70 gal. | Compare for a lower-profile UTV package with separately planned hose deployment. |
| FIRELITE Transport Deluxe FDH-203 | 6.5 HP Darley-Davey: 65 GPM at 48 PSI; 50 at 81; 20 at 120. | 55 or 70 gal. | Compare for UTV deployment with a preconnected, tank-mounted hose reel. |
| FIRELITE Transport Supermax FST-204 | 6.5 HP configuration: 65 GPM at 48 PSI; 50 at 81; 20 at 120. Optional 9 and 13 HP configurations have different performance; obtain the exact curve. | 85 gal. | Compare for more onboard UTV water where cargo capacity supports the complete load. |
Source: linked Darley product listings. Supermax 6.5 HP points come from KIMTEK’s configuration sheet. That sheet contains inconsistent engine labeling; confirm the supplied engine and exact pump curve.
Check vehicle fit and full operating weight
Measure the bed and mounting area, then check cargo-bed capacity, total payload, axle and tire ratings, clearance, and service access. Include water, foam, options, tools, fuel, and occupants against the limits that apply to each load.
On small screens, swipe the table sideways to see every column.
| Model | Dimensions | Published weight | Vehicle fit |
|---|---|---|---|
| Fast Attack 1 - Economy FASU-1E | 94.5 × 48 × 42 in. | 700 lb. listed; dry/wet basis unspecified. | Standard 8-foot pickup bed; confirm loaded installation. |
| Fast Attack 2 - High Pressure FASU-2HP | 94.5 × 48 × 42 in. | 900 lb. listed; dry/wet basis unspecified. | Standard 8-foot pickup bed; confirm loaded installation. |
| Fast Attack 2 - Multipurpose FASU-2MP | 94.5 × 48 × 42 in. | 900 lb. listed; dry/wet basis unspecified. | Standard 8-foot pickup bed; confirm loaded installation. |
| FIRELITE Transport Darley FD-202 | 55 × 48 × 22 in. | 55 gal.: approx. 260 lb. dry / 717 lb. wet. 70 gal.: 270 / 850 lb. | UTV fit and cargo capacity must be verified for the exact vehicle. |
| FIRELITE Transport Deluxe FDH-203 | 55 × 48 × 38 in. | 55 gal.: approx. 324 lb. dry / 790 lb. wet. 70 gal.: 335 / 918 lb. | Verify exact UTV fit, cargo rating, and reel clearance. |
| FIRELITE Transport Supermax FST-204 | 55 × 48 × 41 in. | 6.5 HP: approx. 375 lb. dry / 1,080 lb. wet. Larger engine options add weight. | KIMTEK restricts this model to cargo beds rated over 1,200 lb.; check all additional loads. |
FIRELITE dry/wet figures are approximate manufacturer values without optional foam in this table. See KIMTEK’s weight chart. The Supermax restriction requires a cargo-bed rating over 1,200 lb.; that threshold does not establish capacity for every additional load.
Water adds about 8.34 lb. per US gallon. A full 200-gallon tank carries approximately 1,668 lb. of water alone. Obtain confirmed dry and full operating weights for the exact assembly; the Fast Attack listings do not identify the basis of their stated unit weights.
Match hose deployment and foam to the job
Record nozzle flow and pressure, hose diameter and length, elevation change, appliances, and simultaneous lines. Required pump discharge pressure must cover nozzle pressure plus hose and appliance losses, with an adjustment for elevation. NWCG explains pump-pressure calculations.
On small screens, swipe the table sideways to see every column.
| Model | Hose and discharge setup | Foam option |
|---|---|---|
| Fast Attack 1 - Economy FASU-1E | Electric reel with 100 ft. of 1 in. booster hose; 1.5 in. NST discharge. | Optional around-the-pump or downstream injection. |
| Fast Attack 2 - High Pressure FASU-2HP | Electric reel with 100 ft. of 1 in. booster hose; 1.5 in. NST discharge. | Optional around-the-pump or downstream injection. |
| Fast Attack 2 - Multipurpose FASU-2MP | Electric reel with 100 ft. of 1 in. booster hose; standard 1.5 in. NST discharge. Specify optional 2.5 in. discharge for intended higher-volume duties. | Optional around-the-pump or downstream injection. |
| FIRELITE Transport Darley FD-202 | Hose storage; specify the hose deployment package. Manufacturer lists two gated 1.5 in. discharges. | Optional Scotty through-the-pump system with 5 gal. foam cell. |
| FIRELITE Transport Deluxe FDH-203 | Manual reel: 50 ft. of 1 in. or 100 ft. of 0.75 in. booster hose. Electric rewind optional. | Optional Scotty through-the-pump system with 5 gal. foam cell. |
| FIRELITE Transport Supermax FST-204 | Manual reel: 50 ft. of 1 in. or 100 ft. of 0.75 in. booster hose. Electric rewind optional. | Optional Scotty through-the-pump system with 5 gal. foam cell; one gated 1 in. discharge is unavailable when foam is added. |
Fast Attack options are described in the product listing and linked brochures under Technical references. FIRELITE hose packages and foam options are detailed by KIMTEK: FD-202, Deluxe, and Supermax. Confirm current availability and the final discharge arrangement.
- Longer or uphill hose lays: compare the High Pressure pump against the required flow and calculated pressure.
- Higher-volume duties: confirm supply, suction, tank-to-pump, and discharge capacity. The Multipurpose pump’s higher-flow points are not a promise of that flow through the booster reel.
- UTV deployment: choose hose diameter and reel configuration with hydraulic performance, access, and loaded weight in mind.
- Foam: confirm concentrate compatibility, proportioning range, minimum and maximum flows, flushing requirements, and full foam-cell weight.
Choose tank capacity around your refill plan
More water increases potential operating time and vehicle load. Identify refill locations, expected refill time, and usable onboard water before choosing the tank.
Theoretical discharge time = usable tank gallons ÷ total discharge GPM.
On small screens, swipe the table sideways to see every column.
| Tank | At 20 GPM | At 60 GPM |
|---|---|---|
| 55 gal. | 2.75 minutes | 0.92 minute |
| 70 gal. | 3.5 minutes | 1.17 minutes |
| 85 gal. | 4.25 minutes | 1.42 minutes |
| 200 gal. | 10 minutes | 3.33 minutes |
These calculations assume the full nominal volume is available. They exclude hose filling, reserve water, and other water use. They are not guaranteed operating times or claims that every model supports each flow through the selected hose. Add flows together when operating multiple lines.
Plan winterization before you order
Cold-weather readiness depends on the complete installation. The reviewed product descriptions do not establish a standard freeze-protection package for these six units. Request instructions for the exact assembly.
Fast Attack pickup units
Ask for accessible drainage of the pump, manifold, primer, reel, and any foam equipment. Confirm protection during exposed transport and standby.
FIRELITE UTV units
Include compact plumbing, tank connections, the reel where fitted, and the optional foam circuit. Request storage and return-to-service instructions.
Darley advises draining pump water after use in freezing conditions and checking valves to ensure complete drainage. A frozen pump must thaw before operation. Follow the exact pump and unit manuals. Darley pump FAQ.
- Can every water-containing component be drained accessibly?
- What protection is required during transport and standby?
- What procedures apply to seasonal storage and return to service?
- What temperature limits apply to the chosen foam concentrate?
Get a skid unit matched to your vehicle and hose lay
Send these details with your quote request. Ask Darley to confirm the exact configuration, current pump curve, dry weight, and full operating weight.
- Vehicle: year, make, model, bed dimensions, cargo-bed rating, and available payload.
- Mission: intended use, terrain, access limitations, and rescue-equipment needs.
- Water delivery: nozzle GPM and PSI, hose diameter and length, elevation change, and simultaneous lines.
- Water supply: preferred tank capacity, refill method, and drafting requirements.
- Options: foam, reel, hose storage, lighting, and starting or control preferences.
- Climate and purchasing: minimum temperatures, storage conditions, budget, shipping location, and required delivery date.
Build your skid unit quote
Share your vehicle, hose lay, water supply, and operating needs. Request a configuration that accounts for fit, loaded weight, water delivery, and deployment.
Frequently asked questions
What is a firefighting skid unit?
Darley Fast Attacks and KIMTEK Fire Skids are also referred to as slip-ons, slide-ins, and drop-in units. A firefighting skid unit combines a water tank, engine-driven pump, plumbing, and hose equipment on a platform designed to mount in a compatible pickup, UTV, or other vehicle. Options may include a reel, foam system, storage, or rescue area.
Which skid unit should I consider for a pickup?
Start with the Fast Attack models. Compare Economy against your required performance, High Pressure for greater pressure at the needed flow, and Multipurpose for higher-volume duties. Confirm loaded vehicle capacity before choosing a configuration.
What is the difference between FIRELITE Transport Darley and Deluxe?
Both list 55- or 70-gallon tanks and the same standard pump performance. The FD-202 has a lower published profile; Deluxe adds a tank-mounted, preconnected manual hose reel.
Can a skid unit fit the bed but exceed vehicle capacity?
Yes. Check cargo-bed capacity, total vehicle payload, axle and tire ratings, mounting, and the complete operating load. Water, foam, options, equipment, and occupants all affect the applicable limits.
Does maximum flow happen at maximum pressure?
No. Read each GPM and PSI pair together on the exact pump curve. The highest listed flow and highest listed pressure occur at different operating points.
How long will a skid unit tank last?
Divide usable tank gallons by total discharge GPM for a theoretical estimate. A nominal 200-gallon tank at 20 GPM gives 10 minutes before accounting for hose filling, reserve water, and other use. Actual operating time depends on the installation and operation.
Are foam systems included?
The compared listings describe foam systems as options. Specify the system, concentrate compatibility, proportioning range, foam-cell capacity, flushing requirements, and resulting discharge arrangement in your quote.
Are these skid units winterized as standard?
The reviewed product descriptions do not establish a standard freeze-protection package. Request the exact unit’s draining, storage, transport, and return-to-service instructions, including the reel and foam circuit where fitted.
How much does a skid unit cost?
Darley lists these models as Contact Us for Price. Request a configuration-specific quote covering the unit, options, mounting, freight, and any installation work.
Technical references and product specifications
- Darley skid unit category
- Fast Attack 1 product specifications
- Fast Attack 2 High Pressure specifications
- Fast Attack 2 Multipurpose specifications
- Fast Attack 2 High Pressure brochure
- Fast Attack 2 Multipurpose brochure
- KIMTEK FD-202 specifications and options
- KIMTEK Deluxe specifications and options
- KIMTEK Supermax specifications, options, and cargo restriction
- KIMTEK Supermax configuration sheet
- KIMTEK dry and wet weight chart
- NWCG pump pressure calculation guidance
- Darley pump FAQ and freezing-weather guidance
- Cascade slip-on firefighting units terminology